01 · Symptoms
Does this sound like yours?
- The motor starts at some inlets and does nothing at others
- A particular room or a whole end of the house is dead
- It used to work everywhere
- It works if you hold the hose in a certain way, or only when you wiggle it
- Suction is fine whenever the unit does start
02 · Likely causes
What’s usually behind it
The hose isn’t seated properly
The motor starts when the hose cuff touches two small contact pins inside the inlet. If the hose is only part way in, or is worn at the tip, the contact comes and goes.
Dirty or bent contact pins
Dust builds up on the pins over time, and they can get bent by a heavy-handed hose. The contact becomes patchy, or stops altogether.
A hose that has worn out at the cuff
If the unit starts at every inlet with one hose but not with another, the hose is the fault, not the wall.
A broken wire between the inlet and the unit
Each inlet is connected to the power unit by a thin low-voltage control wire inside the wall. If it’s been cut, pinched or has worked loose behind one inlet, that inlet can’t tell the unit to start. When several inlets on the same run are dead, the break is usually somewhere they share. If nothing starts anywhere, start with the whole-house checks.
A failed inlet
Sometimes the inlet itself has broken: a cracked contact, a snapped hinge, or terminals that have come away. Replacing it means re-connecting the wiring behind the wall plate.
03 · Safe checks
What you can check yourself
Don’t open the power unit
It runs on 240V mains power. The checks below involve the hose and the inlet face only, never the wiring behind the wall plate or inside the unit.
- Switch off at the wall.
Turn the power unit off at its socket first. - Try a working inlet with the same hose.
If the hose starts the unit there, the hose is fine. - Push the hose in fully.
Seat the cuff firmly, give it a slight turn, and see if the unit starts. - Look at the pins.
Open the inlet door and look at the two small metal contacts. Are they bent, loose, or caked with dust? Look only, and don’t touch them with anything metal. - Wipe the inlet.
With the unit still off, brush dust away from the opening with a dry cloth or a dry soft brush. - Make a note.
Write down which inlets work and which don’t. It tells a technician which run of wire to follow.
04 · When to call us
Call now if any of these are true
- The same inlets stay dead after the checks above
- The hose works at some inlets and not others, and you’ve tried a second hose
- The contacts inside an inlet are broken or missing
- An inlet door or faceplate is broken
- Several inlets in the same part of the house have stopped at the same time. That points to a shared wire. Call us and we’ll trace it
FAQ
Is the low-voltage wire dangerous?
It carries only a small control signal, not mains power. Even so, it runs alongside other cables in your walls, so leave it to a technician rather than pulling at it.
Can I just use the inlets that work?
For a while, yes. But the fault won’t repair itself, and a broken inlet can make the others harder to use as well. It’s worth having it looked at.
Does a dead inlet mean a pipe is blocked?
No. A blocked pipe causes weak suction, not no start. If the motor runs but suction is poor, that’s a different problem.