01 · Symptoms
Does this sound like yours?
- Suction is good at most inlets, but one is clearly weaker
- The hose barely holds on to the inlet, or it pulls less strongly than elsewhere
- The same hose works well in another room
- You can hear a faint hiss near that inlet
- The weak spot is always the same inlet, never a different one
02 · Likely causes
What’s usually behind it
The inlet door isn’t closing, or isn’t sealing
Every inlet has a spring-loaded door and a rubber seal. If the door sticks open a crack, or the seal is dirty or worn, air leaks in and steals suction from the rest of the system. It also makes that inlet’s own pull feel weak.
Something at the opening
Socks, toys, hair and bits of paper all find their way to the inlet. A small object sitting just inside the opening restricts airflow without blocking it completely.
The hose or tool you used there
It’s easy to blame the inlet when the hose is the problem. If you’ve used a different hose, wand or floor tool in that room, swap it for the one that works elsewhere before drawing any conclusions. If the hose is the culprit, see how to clear it.
A blockage in the pipe behind the wall
Each inlet has its own length of pipe that joins the main line. Something stuck in that branch cuts suction at that inlet only. It’s the most likely cause when the opening is clear and the seal is fine, and it needs a technician to find and clear.
A leak in that branch of pipe
A loose joint or a crack, for instance from a nail or a picture-hook screw, lets air escape before it reaches the unit. The suction drops at that inlet and often a little at the others too.
03 · Safe checks
What you can check yourself
Don’t open the power unit
It runs on 240V mains power. Checking an inlet is safe once the unit is switched off, but nothing here involves going inside the machine.
- Switch off at the wall.
Turn the power unit off at its socket before you put your fingers anywhere near an inlet. - Try the hose in another room.
If suction is strong there, the hose is fine. If it’s weak everywhere, work through the whole-house checks instead. - Look inside the inlet.
Open the door and shine a torch in. If you can see something sitting near the opening, pull it out by hand. Don’t push anything into the pipe. - Wipe the seal.
Clean the rubber seal and the door with a dry cloth. - Test the door.
It should snap shut on its own. If it hangs open, sticks, or feels floppy, don’t force it. - Switch on and listen.
With the door closed, stand next to the inlet. A hiss means air is getting in somewhere it shouldn’t.
04 · When to call us
Call now if any of these are true
- The inlet is clear, the door and seal look fine, and it’s still weak
- The door won’t close, or the hinge is broken
- You can hear a hiss you can’t stop
- The weak inlet is the one furthest from the power unit and you’re not sure it was ever strong
- You’re not sure what you’re looking at. Give us a call and describe the room and the sound
FAQ
Can a blocked pipe be cleared without cutting into the wall?
Often it can. Blockages in ducted pipework are usually pulled back out through the inlet, so plasterboard stays intact. What’s possible in your home depends on where the blockage is.
Why is only the furthest inlet weak?
Distance matters. The inlet furthest from the power unit has the longest run of pipe, so any small leak or restriction shows up there first. It doesn’t always mean a fault, but it’s worth a look.
Will it get worse if I leave it?
A leaking inlet takes suction from every other inlet, so a small fault tends to spread. A quick look sooner is better than a bigger job later.