01 · Symptoms
Does this sound like yours?
- The suction works, but the powerhead roller stands still
- A light on the powerhead or handle comes on or flashes
- The roller turns slowly, or stops when you press down
- The powerhead works on hard floors but stops on carpet
- Nothing happens when you press the powerhead switch
02 · Likely causes
What’s usually behind it
Hair and fibres on the roller
Hair, thread and carpet fibres wrap around the roller and the ends. When they pack tight, the roller binds and the powerhead stops.
A tripped overload protection
If the roller catches something solid, or bogs down in thick carpet, the powerhead cuts its own power to protect the motor. On many Wertheim models, a reset button on the powerhead restores it. Wertheim overload notes
A loose powerhead connection
If the wand or powerhead doesn’t click fully in, the electrical contacts may not meet. Dust on the contacts can have the same effect.
A snapped or stretched belt
A flat belt drives the roller. When it stretches or snaps, the motor runs but the roller doesn’t turn. On many Wertheim models, the belt sits behind the base plate. Wertheim belt notes
A failed powerhead motor or board
The small motor or control board in the powerhead can fail, especially after hair has strained it. Sealed powerheads are often not worth repairing. If it isn’t, we’ll tell you plainly.
A damaged cable or hose
The wand or hose can carry power to the powerhead. If a wire inside breaks, the powerhead dies, even though the vacuum still runs.
03 · Safe checks
What you can check yourself
Switch off and unplug the vacuum at the wall before you touch the powerhead
Never open the powerhead or the vacuum yourself. It carries 240V.
- Switch off and unplug.
Lay the powerhead on its back on a towel. - Cut the hair.
Use small scissors, and pull out thread and fibres from the ends of the roller. - Clear the roller.
Take out anything stuck around it, then wipe the housing with a dry cloth. - Press the reset button.
If your manual shows a reset button on the powerhead, press it once and wait. - Reseat the connection.
Click the powerhead and wand back in firmly, and wipe the contacts with a dry cloth. - Test it.
Plug in, switch on over a hard floor, and see if the roller turns.
04 · When to call us
Call now if any of these are true
- The roller still won’t spin after the checks above
- The motor runs but nothing turns, which usually means a belt
- The powerhead works only when you hold the wand at an angle
- You smell burning, or see smoke or sparks. Switch off, unplug if it’s safe, and call us
- You’re not sure if the powerhead is worth repairing. Ring us and we’ll tell you honestly
FAQ
Can I replace the belt myself?
Some owners do, if the manual shows how. Where it needs screws and careful refitting, it’s easy to get wrong. That’s a job for a technician.
Why does the powerhead stop on thick carpet?
Thick pile loads the roller, and the overload protection cuts in to save the motor. Lowering the height setting often helps.
Is a new powerhead the only answer?
Not always. A belt or a connection is often a simple fix. If it isn’t worth fixing, we’ll tell you.